@article{45980ce6bd9c4f0a88135489019fbf76,
title = "Fracture Origins in Miniature Silicon Carbide Structures",
author = "Quinn, \{George D.\} and Sharpe, \{William N.\} and Beheim, \{Glenn M.\} and Nemeth, \{Noel N.\} and Osama Jadaan",
note = "Direct tension strength tests were conducted on chemical vapor deposited silicon carbide microspecimens. Three types of specimens were used: straight gage section, tapered gage section, and notched gage section. The average strengths and standards deviations were: 0.42 GPa ± 0.13 GPa; 0.47 GPa ± 0.16 GPa; and 0.68 GPa ± 0.19 GPa, respectively.",
year = "2005",
month = jul,
day = "1",
doi = "10.4028/www.scientific.net/KEM.290.62",
language = "American English",
volume = "290",
journal = "Key Engineering Materials",
issn = "1013-9826",
}